Replacement CT Tubes

Philips Allura Xper FD20

NEW! The Chronos Imaging CL200 Cardiovascular CT replacement tube has dual focal spots of 0.9 x 0.9 and 1.2 x 1.1. It is intended as a replacement tube for Philips Allura Xper FD20 scanners. This tube/insert has a kiloheat unit (kHU) rating of 7,000 kHU. This product is available for shipment and use outside the United States ONLY! Availability begins January 2026. 

Instructions for Use (IFU)

GE LightSpeed series

The Chronos AU-200 CT replacement tube has dual focal spots of 0.9 x 0.7 and 1.2 x 1.1. It is intended as a replacement tube for BrightSpeed™ Edge, BrightSpeed™ Elite, BrightSpeed™ Excel, Discovery™ NM/CT 670, Discovery™ NM/CT 670 Pro, Discovery™ ST, Discovery™ STE, Discovery™ RX, LightSpeed™ 16, LightSpeed™ Plus, LightSpeed™ Ultra and Optima™ CT540 scanners. This tube/insert has a kiloheat unit (kHU) rating of 6,300 kHU.

Instructions for Use (IFU)

GE Optima 660

The Chronos AU200-C40 CT X-Tay tube has dual focal spots of 0.9 x 0.7 and 1.2 x 1.1. It is intended as a replacement tube for Optima™ CT660 scanners. This tube/insert has a kiloheat unit (kHU) rating of 6,300 kHU.

Instructions for Use (IFU)

GE VCT series

The Chronos AU240 CT replacement tube has dual focal spots of 0.7 x 0.6 and 0.9 x 0.9. It is intended as a replacement tube for Discovery™NM/CT570c , Discovery™ VCT, LightSpeed™ Pro32, LightSpeed™ VCT, LightSpeed™VCT Select,  LightSpeed™ VCT XT, LightSpeed™ VCT XTe,  LightSpeed™Pro16, Optima™ CT580 scanners. This tube/insert has a kiloheat unit (kHU) rating of 8,000 kHU.

Instructions for Use (IFU)

GE HiSpeed CT/e series

The Chronos DA135 CT/e CT replacement tube has a single focal spot of 0.7 x 0.6. It is intended as a replacement tube for Brivo CT315, Brivo CT325, Brivo CT385, HiSpeed CT/e, HiSpeed CT/e Dual™ , Revolution™ ACT scanners. This tube/insert has a kiloheat unit (kHU) rating of 2,000 kHU.

Instructions for Use (IFU)

GE HighSpeed/Optima

The Chronos Imaging DA165NP CT replacement tube has dual focal spots of 0.9 x 0.7 and 1.2 x 1.2. It is intended as a replacement tube for BrightSpeed™ Edge Select/Lite, BrightSpeed™ Elite Select/Lite, BrightSpeed™ Excel Select/Lite, HiSpeed DX/I, HiSpeed FX/I, HiSpeed LX/I, HiSpeed NX/I, Optima™ CT520, Optima™ CT520 Pro scanners. This tube/insert has a kiloheat unit (kHU) rating of 3,500 kHU.

 

Instructions for Use (IFU)

Replacement CT Tubes Compatibility Table

Compare Lighthouse replacement tubes with their OEM equivalents. All models are engineered for full system compatibility and long service life.

Image Model OEM Equivalent System Compatibility Anode Heat Capacity Details
AU240 Replacement CT Tube AU240 Replacement Tube MX200 / Dunlee CTR200 GE Lightspeed / Discovery CT 5.0 MHU
CX180 Replacement CT Tube CX180 Replacement Tube MX135 / Dunlee CTR135 Philips Brilliance CT 3.5 MHU
TX300 Replacement CT Tube TX300 Replacement Tube MX240 / Dunlee CTR240 Siemens SOMATOM Series 6.3 MHU

* All product names, logos, company names, and trademarks mentioned in this document, including but not limited to GE® and Siemens®, are the property of their respective owners. Reference to these products is for informational purposes only and does not imply any affiliation, sponsorship, endorsement, or recommendation by the trademark holders. Lighthouse  Imaging Solutions, LLC and its affiliates disclaim any liability arising from the use of or reliance on such references.