Chronos CL200 Replacement CathLab X-Ray Tube

Direct 9.4 MHU OEM Replacement for Philips Allura Xper FD20 Systems (Philips MRC200 0407)

🌐
International Shipping Notice: The Chronos CL200 replacement tube is available exclusively for shipment to and clinical use at destinations outside the United States.
Chronos CL200 Replacement CathLab X-Ray Tube Housing for Philips Allura Xper FD20 🔍 Expand
Chronos CL200 Tube
  • Direct OEM Replacement: Exact fit for Philips MRC200 0407 assemblies
  • High Thermal Storage: 9.4 MHU capacity for heavy CathLab workloads
  • US Engineered: Manufactured in the USA by Chronos Imaging LLC
  • 12-Month Warranty: OEM-level factory coverage backed by Chronos
  • Global Logistics: Reinforced export crate with full customs compliance

The Chronos CL200 delivers exceptional cardiovascular diagnostic image quality while reducing tube replacement costs for high-volume international CathLab centers and hospitals.

Key Technical Parameters

  • Thermal Resilience: 9.4 MHU (7.05 MJ) anode heat storage capacity engineered for continuous interventional procedures.
  • Precision Optics: Focal spot ratings of 0.4 mm (Small) and 0.7 mm (Large) per IEC 60336:2020.
  • High-Voltage Peak: Maximum nominal operating voltage of 125 kV.
  • Anode Construction: 200 mm (7.9 in) TZM disk with an 11.0° target angle for efficient heat dissipation.
  • Documentation & QA: Packaged and shipped with complete Instructions for Use (IFU) and installation instructions.
Note: This product is a component replacement for CathLab scanners. It is not intended by the manufacturer to be marketed with claims of diagnostic benefit or to replace imaging system clinical protocols. Follow the IFU and the scanner OEM service instructions for installation, warm-up, and QA.

Request Pro Forma Quote

Submit your system details below for fast technical verification, pricing, and export dispatch availability.

    Rapid Tube Exchange & Quotation

    Enter your system details below for immediate technical verification and pricing.


















    ⚡ Guaranteed Response: Under 24 business hours | 24/7 Urgent AOG Dispatch Support

    × Chronos CL200 Tube High Resolution Inspection View

    Key Performance & Service Advantages

    ⚡ 9.4 MHU Heat Capacity
    Engineered for high patient throughput and continuous interventional CathLab procedures without thermal throttling.
    Rated 7.05 MJ (9.4 MHU); performance matches original OEM operating limits.
    🔧 Direct OEM Compatibility
    Seamless drop-in replacement for Philips Allura Xper FD20 systems using Philips MRC200 0407 tube assemblies.
    Mechanical and high-voltage electrical interfaces align exactly with factory specs.
    🛡️ Proven Reliability & 12M Warranty
    Rigorously tested for smooth anode rotation, consistent exposure output, and extended operational lifespans.
    Includes standard 12-month factory coverage backed by Chronos Imaging.
    🔌 Simplified Field Integration
    Fully compatible with existing Philips gantry mounting hardware, cooling oil circulation lines, and cable connections.
    Reduces installation downtime; requires qualified biomedical field service engineers.
    📋 Traceable QA & Full IFU
    Packaged with complete Instructions for Use (IFU), serialization tracking, and recommended warm-up procedures.
    Ensures full regulatory compliance and hospital quality management logging.
    🌐 Dedicated International Export
    Shipped in shock-protected, reinforced wooden crates (310 lbs / 140 kg) engineered for safe international air and ocean transit.
    Available exclusively for destinations outside the United States.

    Technical Specifications

    Review engineering parameters to confirm fitment and operating specs before ordering or installation.

    1. Electrical & Thermal Performance
    Nominal Voltage125 kV (max)
    Anode Heat Storage Capacity7.05 MJ (9.4 MHU)
    Small Focal Spot (IEC 60336:2020)0.4 IEC 60336:2020
    Large Focal Spot (IEC 60336:2020)0.7 IEC 60336:2020
    Nominal Anode Input Power (Small Focal)30 kW @ 1.0 sec
    Nominal Anode Input Power (Large Focal)65 kW @ 1.0 sec
    Max Filament Operating Current (Small)6.2 A
    Max Filament Operating Current (Large)6.0 A
    2. Mechanical & Optical Construction
    Anode MaterialTZM, W, Re
    Anode Disk Diameter200 mm (7.9 in)
    Anode Angle11.0°
    X-Ray Tube Window MaterialUltem
    Minimum Total Filtration2.5 mm Al Equivalent
    3. Compliance, Regulatory & Shipping
    Applicable StandardsIEC 60613, IEC 60522, IEC 60336, EN 0601-1-3, IEC 60878
    Shipping Weight310 lbs (140.6 kg)
    Crate Dimensions41" × 27" × 27" (104 × 69 × 69 cm)

    CL200 System Cross-Reference Table

    Confirm direct drop-in fitment for your Philips CathLab imaging platform and tube model.

    OEM Scanner LineCompatible OEM Tube & Model NumbersDirect Action
    Philips Allura Xper Series
    Allura Xper FD20 Systems
    Tube Model: Philips MRC200
    OEM Part #: 0407 / 9890-000-04071
    Request Quote & Fitment