Chronos AU200-C40 Replacement CT Tube for GE Systems

Direct OEM Drop-In Replacement Validated Specifically for GE Optima CT660 Scanners

Chronos AU200-C40 Replacement CT Tube for GE Optima CT660 🔍 Click to zoom
Chronos AU200-C40 CT Tube Assembly (Performix 40 Plus)
  • Optima CT660 Validated: Exact physical & electrical fit for Performix 40 Plus housing configurations
  • US Engineered: Manufactured in the USA by Chronos Imaging LLC under ISO 13485 standards
  • Full Warranty: Includes comprehensive 12-month factory coverage
  • Fast Dispatch: Priority export shipping with full international documentation
  • 24/7 Tech Support: Biomedical engineering assistance available worldwide

The Chronos AU200-C40 is a high-performance replacement CT X-Ray tube engineered to deliver exceptional diagnostic image quality while reducing operational maintenance costs for GE Optima CT660 scanner suites.

Key Technical Specifications
  • Performix 40 Plus Housing Fitment: Factory engineered for seamless electrical, mechanical, and cooling integration with GE Performix 40 Plus housing.
  • Thermal Resilience: High-capacity anode heat storage engineered for continuous high-throughput clinical workflows.
  • Precision Focal Spots: Calibrated focal spot dimensions aligned with OEM scanning protocols.
  • High-Voltage Operating Ceiling: Maximum operating voltage rated at 140 kV to handle demanding slice protocols.
  • System Calibration Integration: 100% plug-and-play compatibility with GE Optima CT660 system calibration software.
Note: This product is a component replacement for CT scanners. It is not intended by the manufacturer to be marketed with claims of diagnostic benefit or to replace imaging system clinical protocols. Follow the IFU and the scanner OEM service instructions for installation, warm-up, and QA.

    Rapid Tube Exchange & Quotation

    Enter your system details below for immediate technical verification and pricing.


















    ⚡ Guaranteed Response: Under 24 business hours | 24/7 Urgent AOG Dispatch Support

    × Enlarged View

    Key Performance & Service Advantages

    Engineered for high-volume diagnostic centers operating GE Optima CT660 scanner suites.

    ⚡ Thermal Performance & Endurance
    High-capacity anode heat storage designed for demanding clinical workflows, continuous slice acquisitions, and trauma protocols.
    Optimized anode heat dissipation tailored to GE Optima CT660 duty cycles.
    🔧 Performix 40 Plus Direct Drop-In Fit
    Direct mechanical, optical, and high-voltage electrical replacement engineered specifically for Performix 40 Plus housing assemblies on GE Optima CT660 systems.
    100% verified drop-in match for GE Optima CT660 gantries.
    🛡️ Proven Reliability & 12-Month Warranty
    Subjected to rigorous anode rotation, focal spot alignment, and radiation stability testing. Manufactured in Aurora, Illinois under ISO 13485 certification.
    Includes 12-month full factory coverage backed directly by Chronos Imaging.
    🔌 Seamless Field Installation
    Integrates directly into GE Optima CT660 gantry mounts, oil cooling lines, HV receptacles, and system calibration routines.
    Minimizes scanner downtime; requires installation by qualified service engineers.
    📋 Quality Control & IFU Protocols
    Individually packaged with serialized quality test reports, manufacturer Instructions for Use (IFU), and step-by-step season-in protocols.
    Ensures strict regulatory compliance and smooth medical physics sign-off.
    🌐 Worldwide Priority Shipping
    Shipped in shock-isolated, heavy-duty reinforced wooden export crates engineered for international air freight and customs clearance.
    Priority dispatch with complete export documentation and tracking support.

    Technical Specifications

    Review engineering parameters to confirm fitment and operating specs before installation on GE Optima CT660 systems.

    1. Electrical & Thermal Performance
    Nominal Voltage140 kV (max)
    Anode Heat Storage Capacity4.7 MJ (6.3 MHU)
    Small Focal Spot (IEC 60336:2005)0.7 × 0.6 mm
    Large Focal Spot (IEC 60336:2005)0.9 × 0.9 mm
    Anode Input Power (Small Focal)24 kW @ 1.0 sec
    Anode Input Power (Large Focal)53.2 kW @ 1.0 sec
    Max Filament Operating (Small)8.1 V, 7.5 A
    Max Filament Operating (Large)11.4 V, 6.5 A
    2. Mechanical & Optical Construction
    Anode MaterialTZM, W, Re, Graphite
    Anode Disk Diameter200 mm (7.9 in)
    Anode Angle7.0°
    Housing InterfaceGE Performix 40 Plus Housing Assembly
    Validated CT SystemGE Optima CT660 Series
    X-Ray Tube Window MaterialBeryllium
    Min Inherent Filtration<0.1 mm Al Equivalent
    3. Compliance, Regulatory & Shipping
    Applicable StandardsIEC 60336, IEC 60522, IEC 60613, IEC 60878, EN 60601-1, EN 60601-1-3, EN 60601-2-28, UL 60601-1, ISO 13485, US FDA 21 CFR
    Safety ClassificationFDA Class I, IEC 60601-2012 IB, 93/42/EEC IIB
    Shipping Weight330 lbs (149.7 kg)
    Crate Dimensions41" × 28" × 29" (104 × 71 × 74 cm)
    📄

    Technical Compliance & Manufacturer IFU Supplement

    Access official manufacturer Instructions for Use (IFU) covering mechanical Performix 40 Plus housing specifications, thermal limits, and pinout configurations for the Chronos AU200-C40 series.

    Download Chronos AU200-C40 IFU Supplement (PDF) →

    Chronos AU200-C40 Cross-Reference Table

    Verify your GE scanner model and housing configuration to confirm direct drop-in fitment.

    Validated OEM Scanner LineCompatible OEM Tube & Housing AssembliesDirect Action
    GE Optima™ CT660 Series
    (Validated exclusively for Optima CT660 platforms)
    Housing: Performix 40 Plus Housing
    Tube Type: Chronos AU200-C40 Assembly
    Request Quote & Fitment